Pine fruits (except pears) in thiamethione colloidal gold rapid detection card instruction manual
Product number
: YB083C01K
Product Overview
Thiamethione is a neonicotinoid insecticide that mainly acts on the nervous system of insects. It can selectively bind to nicotinic acetylcholine receptors in insects, block the transmission of nerve signals, and finally kill pests. It has the characteristics of high efficiency, strong internal absorption, long shelf life, and high safety. It is widely used in pest control of pomegranate fruits such as apples and begonia fruits.
This product is a special thiamethione colloidal gold rapid detection card for kernel fruits (except pears). It is optimized for the characteristics of pulp and peel matrix of apples, begonia fruits, etc. It can quickly complete the on-site initial screening of thiamethione pesticide residues in samples. It is easy to operate and does not require large instruments. It is suitable for various fruit planting, processing, circulation and market supervision sampling scenarios.
Second, the detection principle
This product adopts the principle of competitive inhibition immunochromatography. The binding of thiamethione in the sample to the specific antibody labeled with colloidal gold inhibits the binding of the antibody to the antigen on the NC membrane detection line (T line), resulting in the change of the color depth of the T line. The operator can judge the residual content of thiamethione in the sample by comparing the color depth of the T line and the C line.
III. Product use
Mainly used for apples, begonia fruits, etc
Fruits (except pears)
The rapid qualitative primary screening of thiamethione content in fresh samples is also suitable for the screening of thiamethione residues in various fresh vegetable and fruit samples, which can meet the needs of enterprise self-inspection, origin screening, market sampling and other testing needs.
IV. Product technical indicators and performance
1. Minimum detection limit for samples
0.01 mg / kg (ppm)
2. Cross-reactivity
This product has good specificity and strong anti-interference ability: the crossover rate with imidacloprid is about 1.5%; the crossover rate with furfuran, amidacloprid, thiamethoxam, and polymycin is less than 0.5%, effectively avoiding the interference of similar pesticides, and the detection results are stable and reliable.
V. Kit composition
This kit is divided into 10 times/box and 20 times/box. The accessories are complete and ready to use. The specific configuration is as follows:
serial number | component parts | 10 times/box | 20 times/box |
|---|---|---|---|
1 | Test card (1T/individually packaged) | 10 Card | 20 cards |
2 | Pesticide residue extract (100 mL/bottle) | 1 bottle | 2 bottles |
3 | 2 mL centrifuge tube | 10 sticks | 20 sticks |
4 | Product instruction manual | 1 serving | 1 serving |
VI. Precautions
1. Tools such as knives, scissors, and stickers for pre-testing samples should be cleaned to avoid cross-contamination.
2. Samples should be made of fresh and intact pomegranate fruits to avoid the use of spoiled and deteriorated samples; large pieces of dirt and impurities attached to the surface of the sample should be cleaned to prevent affecting the extraction and detection results.
3. Before testing, it is recommended that the samples be fully stirred and mixed. When sampling, select the representative parts of the fruit for weighing and testing to ensure that the test results truly reflect the actual drug residue of the sample.
4. The test environment temperature should be controlled at 17 to 30 degrees Celsius. Excessive or too low temperature will affect the color rendering of the test paper and cause deviation in the test results.
5. Please strictly follow the testing steps for testing. Do not touch the color-rendering area of the test strip during operation. Avoid direct sunlight and electric fans blowing the test strip directly during the testing process.
6. The sample solution to be tested needs to be kept clear. The turbidity of the solution can easily lead to inconspicuous color development and abnormal background, which will affect the judgment of the experimental results.
7. Products that have expired or the aluminum foil bag is damaged cannot be used. Please use the test card after unpacking immediately and cannot be stored for a long time.
8. Please complete the test as soon as possible after the sample is processed. If the storage time is too long, the sample needs to be reprocessed before testing.
9. When a positive result appears, it is recommended to retest. The test results of this product are for initial screening reference only. If accurate confirmation is required, it needs to be tested with reference to relevant national standards and methods.
10. When adding standards for verification, methanol is generally selected as the solvent for the standard solution, and the final sample addition is recommended to be controlled at 10-50 μL.
11. When directly testing the standard, the solvent needs to be extracted with the kit, and the amount of organic solvent added is controlled within 1%. Tap water, distilled water, purified water or deionized water cannot be used as negative controls.
VII. Safety instructions
1. The experimental operation needs to be equipped with corresponding experimental equipment, and the operator needs to wear the necessary experimental equipment such as experimental white clothes, gloves, and masks to standardize the operation.
2. The test kit should be properly stored and placed in a place that is not easily accessible to children to prevent accidental ingestion.
3. After the experiment, keep the experimental table clean and maintain air circulation in the experimental environment.
4. This product is a one-time use product and cannot be reused. After the test is completed, the experimental waste needs to be collected separately, and it is recommended to dispose of it according to the medical waste specification.
5. The reagents involved in this product are safe and reliable, and do not contain carcinogenic, highly toxic, flammable, explosive, and highly corrosive ingredients, but consumption is strictly prohibited.
Storage conditions and valid period
1. Original packaging: dry storage at 4-30 ° C away from light, no freezing, valid period of 12 months.
2. After unpacking: The test card needs to be used immediately after unpacking, and freezing is prohibited.