Thiomycin Colloidal Gold in Eggs Rapid Detection Card Instruction Manual

2025-12-14

YB156D01K _ _ eggs _10ppb_ _0 + 4ml_YP_20250924

Thiomycin Colloidal Gold in Eggs Rapid Detection Card Instruction Manual

Product number:
YB156D01K

summary

thiamphenicol

Florfenicol (FF), also known as fludisomycin, is a new generation of broad-spectrum antibiotics for chloramphenicol animals, and is a commonly used antibacterial agent in livestock and poultry breeding.
thiamphenicol
Amine (
Florfenicol amine,FFA)是
thiamphenicol
The main residue in the animal body,
thiamphenicol
It has embryonic toxicity, and adverse reactions such as anorexia and diarrhea will occur after use. Therefore, our country and the European Union have stipulated
thiamphenicol
MRLs in various target tissues of different animals.

Detection principle

thiamphenicol
The detection card is used to rapidly detect the presence of
thiamphenicol
Residue. This product is made using the principle of competitive inhibition colloidal gold immunochromatography and is used in testing samples
thiamphenicol
After the sample solution is dropped into the sample hole of the test card, the
thiamphenicol
It binds to the gold-labeled antibody, thereby preventing the gold-labeled antibody from interacting with the cellulose membrane
thiamphenicol
The conjugate binds. According to
T line and C line color depth judgment results.

Scope of application

This product is suitable for use in fresh poultry eggs
thiamphenicol
Qualitative detection of residues.

Note: The types of test samples refer to the national standard
GB2763-2021

detection limit

10 μg / kg (ppb)

Kit composition

serial number

Specifications

composition

10 times/box

20 times/box

(1)

Detection card
(Contains dropper, desiccant)

10 servings

20 servings

(2)

diluent

1 bottle

2 bottles

(3)

10mL
detection tube

10support

20support

(4)

1 mL disposable straw

10 sticks

20 sticks

(5)

manual

1 serving

1 serving

Precautions


1) Before each sample inspection, the knives used to cut the sample should be cleaned to avoid cross-contamination.


2) The test environment temperature should be controlled at 20 to 30 degrees Celsius. If the temperature is too high or too low, it will affect the test results.


3) Please follow the detection steps for testing. Do not touch the color rendering area of the test strip during operation, and avoid direct sunlight and direct blowing of the electric fan.


4) Please use the sample as soon as possible after processing. If it takes too long, you need to reprocess the sample for testing.


5) The sample solution to be tested needs to be clarified, otherwise it will easily lead to abnormal phenomena such as insignificant color development, which will affect the judgment of the experimental results.


6) Products that have expired or the aluminum foil bag is damaged cannot be used. Please use the test card immediately after unpacking.


7) This product is a one-time product, please do not reuse or mix test cards from different batches.


8) When a positive result appears, it is recommended to retest. The test results of this product are for reference only. If you need confirmation, please refer to the relevant national standards and methods.


9) During product evaluation, if you need to directly test the standard product, you need to prepare it with a special diluent in the kit.


10) Tap water, distilled water, purified water, or deionized water cannot be used as a negative control.

safety instructions


1) The experiment needs to match the corresponding experimental equipment and wear the necessary experimental equipment (white clothes, gloves, masks, etc.).


2) The test kit needs to be stored in a place that is not easily accessible to children, and do not eat the equipped reagents.


3) All items used in the experiment should be properly disposed of after application.


After the experiment, maintain the cleanliness of the laboratory and the flow of air in the experimental environment.


5) Experimental waste is collected separately, and it is recommended to treat it as medical waste.

Storage conditions and valid period


Storage conditions: Store at 2-30 ° C away from light, do not freeze.


2) valid period: 12 months.