Fenthion Colloidal Gold Rapid Detection Card Instruction Manual

2025-09-24

Fenthion Colloidal Gold Rapid Detection Card Instruction Manual

Product Number: YB102C01K

Summary


Fenthion (Fenthion) is an organophosphorus insecticide, which is more toxic to dogs and poultry, highly toxic to bees, no chronic toxicity, and low toxicity to humans and animals. It has contact and gastric toxicity to pests, and has a certain permeability to crops, but no internal absorption conduction effect, broad-spectrum insecticide, and rapid effect.

Detection Principle


This product adopts the principle of competitive inhibition immunochromatography. The fenthion in the sample binds to the specific antibody labeled with colloidal gold, which inhibits the binding of the antibody to the antigen on the NC film detection line (T line), resulting in the change of the color depth of the T line; according to the color development depth of the T line and the quality control line (C line).

Scope of application


This product is suitable for qualitative detection of fenthion residues in fresh vegetables, fruits and other samples.

Note: The types of test samples refer to the national standard GB2763.

Detection limit


0 mg/kg (ppm)

Kit Composition


Serial number

Specification
Composition

1 0 times/box

20 times/box





(1)

Detection card (containing dropper, desiccant)

10 card

20 card





(2)

Gold standard micropore (10 holes/cartridge)

10 hole/cartridge

20 hole/cartridge





(3)

dilution (55mL/bottle)

1 bottle

2 bottle





(4)

20mL graduated sample cup

2

4





(5)

10 centrifuge tube

20





(6)

5 mL rubber Cleaning to avoid cross-contamination.

(2) Sample requirements: Avoid spoilage and deterioration of the sample; avoid large pieces of soil (can be thrown off or wiped with other clean items).

(3) Before testing, it is recommended that the sample be fully stirred and mixed (if the sample is less, it should be taken representative parts, and then weighed), so that the test results can more accurately reflect the actual drug residue of the sample.

(4) The test environment temperature should be controlled at 20~ 30 ℃, too high or too low temperature will affect the test results.

(5) Please follow the test steps to test, do not touch the color zone of the test strip during operation, and avoid direct sunlight and direct blowing of electric fans.

(6) The sample solution to be tested needs to be clarified, otherwise it will easily lead to abnormal phenomena such as inconspicuous color development and affect the determination of experimental results.

(7) Products that have expired or damaged aluminum foil bags cannot be used. Please use the test card immediately after unpacking.

(8) Please use the sample as soon as possible after processing. If the time is too long, you need to reprocess the sample for re-testing.

(9) When a positive result occurs, it is recommended to retest. The test results of this product are for reference only. If you need to confirm, please refer to the relevant national standards and methods.

(10) When adding standards for verification, the solvent of the standard solution is generally methanol, and the final sample is recommended to add 10-50 μL.

(11) When directly testing the standard, the solvent should be used to match the extract of the kit. The amount of organic solvent added is controlled within 1%. Tap water, distilled water, purified water or deionized water cannot be used as a negative control.

Safety instructions


(1) The experiment should match the corresponding experimental equipment and wear the necessary experimental equipment (white clothes, gloves, masks, etc.).

(2) The test kit should be properly stored. Please put it in a place that is not easy for children to contact.

(3) After the experiment, keep the laboratory clean and the air flow of the experimental environment.

(4) This product is a disposable product. After the test, it should be properly disposed of. The experimental waste should be collected separately. It is recommended to dispose of it according to the medical waste.

(5) The reagents involved in this product are safe and reliable, and do not contain carcinogenic, highly toxic, flammable, explosive, and highly corrosive reagents, but should not be eaten.

storage conditions and valid period


(1) Original packaging: Store dry at 2-30 ° C in the dark, do not freeze, valid period 12 months.

(2) After unpacking: Use the test card immediately after unpacking, do not freeze.