Propofos Colloidal Gold Rapid Detection Card

Product code: YB103C01K
Product Inquiry
Propionophos colloidal gold quick test card, based on competitive inhibition immunochromatography technology. Detect microporous pre-lyophilized gold-standard antibody, nitrocellulose membrane T-line coated with propiono...
Product details

Propofos Colloidal Gold Rapid Detection Card Instruction Manual


1 Principle and Use

This product is made of the principle of competitive inhibition of colloidal gold immunochromatography for the detection of propofos pesticide residues in vegetables and fruits. After the sample solution is dropped into the sample hole of the detection card, the propofos in the sample solution are combined with the gold standard antibody, thereby preventing the gold standard antibody from binding to the propofos conjugate on the cellulose membrane. The detection result is judged by the color depth of C and T lines.

2 technical indicators

Detection sensitivity: 5 mg/kg (ppm)

3 Need to bring your own tools

Electronic balance (0.1-100 grams), scissors, forceps, disposable cups, vortex mixer, pipette (0.1-1 ml), timer.

4 sample pretreatment

Take an appropriate amount of sample, cut about 1 cm square, weigh 1 gram of shredded sample in a 5 ml detection tube, add 1 ml of diluent, fully oscillate for 10 seconds, let stand for 5 minutes, as the liquid to be tested;

5 sample testing

(1) Tear open the aluminum foil packaging bag of the detection card, take out the detection card/gold microporous/dropper (a total of 3 kinds of consumables), and place it on a flat and clean countertop.

(2) with a pipette or aluminum foil bag matching dropper to absorb the liquid to be tested 120 µL (about 4 drops) in the gold standard micropores, blown with a dropper to completely dissolve the purplish-red material in the pores, let stand horizontally, and wait for the reaction for 2 minutes; all the liquid in the gold standard micropores is added dropwise to the sample well (S) of the detection card;

(3) Start timing after adding the sample, and leave it at room temperature for 8-10 minutes to judge the result, and other time interpretation is invalid.

6 result judgment

Negative (-): T-line color development is deeper than C-line or there is no significant difference with C-line color development, indicating that there is no substance to be tested in the sample or its concentration is lower than the detection limit.

Positive (+): The color development of the T-line is significantly weaker than that of the C-line or the T-line does not develop color, indicating that the concentration of the substance to be tested in the sample is equal to or higher than the detection limit.

Invalid: No C-line appears, indicating that the operation process is incorrect or the test card has failed. In this case, the instructions should be read carefully again and re-tested with a new test card.

7 Precautions

(1) Products that have expired or damaged aluminum foil bags should not be used.

(2) The test card should be restored to room temperature and opened when taken out of the refrigerator. The opened test card should be used as soon as possible to avoid failure after moisture.

(3) Do not touch the white film surface in the center of the test card.

(4) The liquid extraction dropper should not be mixed to avoid cross-contamination.

(5) Please store the reagent in a place that is not easy for children to contact, and do not eat the equipped reagent.

(6) If you need to directly test the standard product, please prepare it with the dilution provided in the kit.

8 Storage and shelf life

(1) Storage conditions: 4-30 ° C Store in the dark, do not freeze.

(2) Shelf life: 1 year, see the outer packaging for the production date.

9 kit composition

Specification

Composition

10 times/box

20 times/box

Test card (containing gold standard micropores, droppers, desiccant)

10 parts

20 parts

Propofos dilution

1 bottle

2 bottle

5 ml test tube

10 pieces

20 pieces

20 pieces 1

Product Inquiry